Power
Cord Swing Tester Bending Test Machine Wire & Cable Testing Swing
Machine 110V |
|
|
|
|
|
|
 |
|
Product
Overview |
| The wire bending testing machine
is suitable for the bending tests or swing tests of plug
pinouts, power cords, USB cables, headphone cables, audio
cables, earphone wires and other product wires. The specimen is
fixed to the fixture, a certain load is added, the specimen
swings left and right during testing, the broken wire rate of
the specimen is detected after the specimen swings for a certain
number of times, the total number of swings can be seen,
automatic counting can be achieved, and the machine can
automatically stop operation after the specimen is bent to be
broken and cannot be electrified. The machine meets the
regulations of ‘General Safety Requirements for Cord Sets and
Power Supply Cords’ of UL817 and ‘General Technical
Specification for Over-ear Headphones - GB/T 14471-93’. |
|
|
Product
Parameters |
|
Working power supply |
AC110V 60HZ |
|
Test station |
6 groups (simultaneous testing) |
|
Bending angle |
0-180˚ (scale dial + indicator pin, manually
adjustable) |
|
Bending angle display and adjustment |
Indicator pin indicates the scale dial, manual
adjustment of eccentric shaft |
|
Test speed |
10-60 times/min (speed adjustment, LCD display) |
|
Swing number total counter |
0-999999 times (can be preset, automatically
stops when the number is reached) |
|
Swing breakover counter |
0-999999 times
(breakover is counted automatically and separately, one group is
disconnected, and counting is automatically stopped.) |
|
Weights with hooks |
50g*6, 100g*6, 200g*6, 300g*6 and 500g*6 |
|
Handle test fixtures |
Six sets of special fixtures that are anti-slip
and not prone to damaging the sample. |
|
Test fixing rod |
It can be adjusted up and down to fix the lower
end of the product, making the test better meet the standards. |
|
Machine size (L×W×H) |
85×60×75cm (33.5x23.6x29.5 inches) |
| Net weight |
76.5kg (168.6LBs) |
|
 |
|
Attention |
|
1. Before using the machine, place it on the
solid ground.
2. Do not move the machine during testing.
3. Select the appropriate supply voltage to avoid
damage to the machine.
4. When the machine is abnormal, please contact
after-sales personnel timely to solve problems.
5. When the machine is working, ensure good
ventilation.
6. Regularly lubricate the mechanical parts.
7. After each test, wipe the machine and keep the
machine clean.
8. Clean the control box with dry cloth, not with
damp cloth. |
|
|
Product
Features |
|
|
|
Control Panel
The
LCD touch control screen is easy to operate and accurate to
control, effectively achieving accurate parameter setting,
real-time monitoring of test data and convenient data management
and greatly improving the testing efficiency, precision and
reliability. |
|
Indicator Lights
The
six indicator lights are designed to correspond to six testing
stations, facilitating independent monitoring of the testing
states, greatly improving the working efficiency and the quality
management level and ensuring clear and direct state indication. |
|
Fixtures
The six fixture groups are used to achieve
batch testing, greatly shortening the total testing time, saving
manpower and cost and ensuring the consistency of the testing
conditions. The fixtures are independent, adjustable, firm and
durable.
|
|
|
|
|
Fixing bunches
The
six fixing bunch groups are used to allow the samples to
smoothly pass through, effectively preventing the samples from
deviation during testing, well improving the testing precision
and stability. |
|
Universal Wheels
The
universal wheels make the machine move easily and effortlessly,
the machine can better adapt to different working environments,
the practicability and adaptability are greatly enhanced, and
the machine can be stably fixed through the brakes. |
|
Accessories
The
breakover wires are provided for the breakover testing of wires
and cables, effectively enlarging the application range of the
machine. The 30 weights can be used in different testing
conditions, well meeting the testing requirements of different
wires. |
|
|
Operation
Method |
|
1. Take test samples with the appropriate
lengths, fix one end of each sample in the corresponding
fixture at the top end, and place the other end between
the corresponding clamp bunch on the guide rod. Tie
cross knots at the appropriate positions of the lower
ends of the test samples, and hang the standard weights
as required, and then fix the lower ends of the test
samples one by one with the guide rod fixing wheels, and
connect the test samples with the terminal clamp bunches
of the corresponding groups (remember that the samples
must be clamped with the clamps).
2. Connect the power cord, turn on the
power switch, test the machine, and if there is any
abnormality, turn off the power.
3. Click on the settings on the testing
interface to enter the parameter setting interface, set
various parameters and other related parameter values.
4. Set the number of tests (0~999999
times, can be preset). Click the reset key to return the
previous test count to zero, and then set the test count
according to the test needs. If the new test count is
the same as the previous test count, there is no need to
modify the count.
5. After everything is ready, click the
test key and the machine will start running for testing.
If the machine needs to be temporarily stopped in the
testing process, simply click on the "Stop" key. To
restart, simply click the "Test" key to resume the
operation. If any abnormal situation occurs in the
testing process, please directly press the emergency
stop switch or power switch to stop the test.
6. During the test, please do not perform
any operations on the machine at will, so as not to
affect the test results. When a certain group is broken
during the test, the corresponding counter on the test
panel will stop counting and the machine will
automatically give an alarm (the machine is running
normally at this time and will not affect the tests on
other stations). The test will continue as usual until
the last group is broken or the number of tests reaches
the set value of the total counter. This machine has a
power-off stop counting function. If there is a power
outage, the number of tests will not be reset for the
next test, and the last test can continue.
7. Test type: The life mode or breakover
mode can be selected. When conducting a breakover test,
connect the + line and the – line of the breakover wire
to the corresponding positions on the sample. If the
test interface displays "breakover", it indicates that
the lines are correctly connected in series. If not
connected, it displays disconnection and the machine is
in a standby mode. Before each restart, it is necessary
to reset to the original position, set the speed and
number of tests, and then click on the test key for
testing. (Note: When the large angle is set, the speed
should be set to be low, and then the operator can press
the test key to conduct testing.)
8. After the testing stops, record the
test results. If the product needs to be replaced for
testing, repeat the above steps.
9. After all tests are completed, turn
off the power.
10. Take out the test samples, wipe the
test fixtures and weights clean, then place the weights
and power cord in the storage box, and place the
connecting wires properly. |
|
|
|
Product
Display |
 |
 |
 |
 |
|
Item Number (057305): 1 x Power Cord Swing
Tester 110V |
|
|
You can make
order with no worry.
Any concern just feel free to let us know, we'll reply in 24 hours in
normal condition.
Handling Time: Shipping is usually made in 1-3 business days after
payments cleared. Orders are processed from Monday-Friday; Not on the
weekends & public holidays.
Warranty: 6 months' warranty for the machines, not for the consumables.
We stand behind our products all the item, so even if your warranty
period has expired, you can still seek for service or technical support
from us with low cost. |
|