Product Overview
|
220V
High-Flow Industrial Filter for Electroplating Nickel / Injection
Molding / Chemical Liquids |
|
 |
| This equipment is a vertical
electroplating solution filter designed specifically for the
electroplating industry. It features a 6-core high-flow
filtration design capable of efficiently filtering
electroplating solutions, chemical reagents, and other
industrial liquids. Equipped with a self-priming pump, it
ensures smooth liquid intake; A 220V/750W motor provides stable
power, ensuring long-term continuous operation. Its primary
function is to remove solid impurities, particulates, and
contaminants from the plating solution, maintaining the
solution’s cleanliness. This improves the quality of the plating
layer, reduces product defects, and extends the service life of
the plating solution. It is mainly
used for circulating filtration of electroplating solutions in
the electroplating industry, including nickel plating, chromium
plating, zinc plating, and other processes. It can also be used
in chemical, pharmaceutical, water treatment, and other
industrial scenarios that require filtration of corrosive
liquids. |
1. Efficient Filtration: With a large
flow design, it can quickly complete the filtration tasks of a
large amount of industrial liquid, enhancing production
efficiency; it can effectively remove impurities and suspended
substances in the liquid, ensuring the accuracy and quality of
electroplating and other processes.
2. Corrosion Resistance: The equipment material has the ability
to resist acids and alkalis and is corrosion-resistant, which
can be adapted to various corrosive industrial liquids,
extending the service life of the equipment. |
| Power: |
750W |
| Voltage: |
AC 220V 50-60HZ
Single-phase electricity |
| Filtering
capacity: |
150L/MIN (39.6gal/min)
9T/H (19,842 lbs/h) |
| Applicable
filter tank: |
1-2m3
(35.3-70.6 ft3) |
| Filter
element count: |
20" (50.8cm) *6 |
| Pump: |
Self-priming pump |
| Temperature: |
0-70℃ (32-158℉) |
| Filter
cartridge material: |
FRPP |
| Pump
material: |
FRPP |
| Interface
diameter: |
1.5 inch (38.1 mm) |
1.
Power Matching
Before use, confirm that the power supply is 220V
50/60Hz single-phase, the voltage is stable, and the socket is
properly grounded to prevent motor burnout.
2.
Stable Installation
Place the equipment on a flat, dry, and
well-ventilated surface. Avoid tilting or shaking to prevent
resonance or leakage during pump operation.
3.
Inlet Pipeline Inspection
Before starting the self-priming pump, ensure the
inlet pipeline is well-sealed with no air leaks. The pipeline
must be pre-filled with liquid (especially after initial use or
prolonged downtime), otherwise the pump may fail to draw liquid
properly.
4.
Never Start the Pump without Liquid
Do not start the pump without liquid. Dry running
will damage the mechanical seal due to dry friction and may even
burn out the pump.
5.
Filter Element Installation
When installing the 6 filter elements, confirm the
specifications match (e.g., 20 inches). The sealing rings at
both ends of each filter element must be properly positioned and
tightened to prevent liquid from bypassing the filter elements
and flowing out unfiltered.
6.
Pressure Monitoring
Regularly observe the pressure gauge on the filter
machine during operation. When the pressure rises significantly,
it indicates the filter elements are clogged and need timely
cleaning or replacement.
7.
Liquid Temperature
The pump body and filter elements are made of FRPP.
The applicable liquid temperature shall not exceed 70℃ (158℉).
High-temperature liquids may cause deformation or leakage.
8.
Prevent Corrosive Liquid Leakage
Electroplating solutions are often corrosive. Before
use, inspect all connections, sealing rings, and pipelines for
damage to prevent liquid leakage that could corrode the
equipment or injure personnel.
9.
Regular Filter Element Cleaning
Regularly remove the filter elements for cleaning or
replacement according to the level of contamination in the
solution. Severe clogging will affect flow rate and increase the
pump load.
10.
Motor Protection
Protect the motor from moisture or water spray. Do
not rinse the motor directly with water during cleaning to
prevent short circuits or insulation damage.
11.
Abnormal Shutdown
If the unit produces unusual noise, excessive vibration,
reduced flow, or abnormal pressure increase, stop operation
immediately, disconnect power, and inspect the pump, piping, and
filters. Resume only after resolving the issue.
12.
Long-Term Shutdown
When not in use for an extended period, drain any
residual liquid from the pump body and pipelines. Clean the
filter elements, let them dry, and store them in a dry place to
prevent bacterial growth or component corrosion. |
| Product Details and Advantages |
 |
Integrated
Injection Molding
The body is made of integrated
injection molding, offering strong sealing and
eliminating leakage.
|
High-Flow
Pump
Adopts a high-flow pump with a
copper-wire motor, delivering large flow capacity and
high efficiency.
|
 |
 |
Pump Head
Bracket
Equipped with a pump head bracket
to stabilize the machine body for superior performance.
|
Filter
The filter cartridge assembly
features high filtration accuracy, corrosion
resistance, high flow rate, and easy maintenance,
making it suitable for continuous circulation filtration
of strong acidic or alkaline plating solutions such as
nickel electroplating, effectively removing fine
particles and impurities to ensure coating quality.
|
 |
|
1,Confirm that the installation site is
level, dry, and far away from fire sources. Also, ensure that
the site has good ventilation conditions to facilitate the heat
dissipation of the equipment and the discharge of harmful gases.
2,Check whether all components of the
equipment are in good condition, and inspect for any damage or
looseness in valves, pressure gauges, pipelines, etc. Prepare
the appropriate pipeline accessories, sealing tapes, and other
installation materials.
3,Place the equipment steadily on the
installation site. Use the fixing holes at the bottom of the
equipment and expandable bolts to fix the equipment to the
ground, preventing any shaking during operation.
4,Pipeline connection: The connection
points should be wrapped with sealing tape to ensure a tight
seal without any leakage. The pipeline route should be as smooth
as possible to avoid excessive bends.
5,Professional electricians will connect
the motor to the power supply according to the voltage and power
parameters of the equipment, ensuring that the circuit wiring is
firm and the insulation is good. At the same time, an earth
leakage protection device will be installed.
6,Before starting the machine, perform a
check. Ensure that all valves are in the correct initial
position. Typically, the liquid inlet valve and outlet valve
should be closed, while the slag discharge valve should be open.
Check if the pointer on the pressure gauge has returned to zero
and confirm that there is no blockage in the pipeline.
7,During operation, regularly check for
any leaks in the pipelines and ensure that the valves are
functioning properly. In case of abnormal pressure increase or
decrease, or abnormal noises from the equipment, immediately
stop the machine to troubleshoot the problem.
8,Shutdown operation: First, close the
inlet valve to stop the drug liquid input. Let the equipment
continue to run for 1-2 minutes to discharge the remaining drug
liquid in the pipeline. Then, close the outlet valve. Finally,
turn off the equipment power supply and cut off the circuit. |
| Product Presentation & Details |
|
220V High-Flow Industrial Filter for Electroplating Nickel /
Injection Molding / Chemical Liquids *1 |
|
You can
make order with no worry.
Any concern just feel free to let us know, we'll reply in 24
hours in normal condition.
Handling Time: Shipping is usually made in 1-3 business days
after payments cleared. Orders are processed from Monday-Friday;
Not on the weekends & public holidays.
Warranty: 6 months' warranty for the machines, not for the
consumables.
We stand behind our products all the item, so even if your
warranty period has expired, you can still seek for service or
technical support from us with low cost. |
|